-40%
220 Volt/50Hz AC Power Source - Step-Up Voltage & Frequency Converters
$ 894.95
- Description
- Size Guide
Description
220 Volt/50Hz AC Power SourceStep-Up Voltage & Frequency Converters
The Best Quality Voltage Converter and Frequency Converter!
Input Range: 100Vac- 285Vac
Input Frequency: 50Hz/60Hz Automatic
Output: 200V-220V-230V-240V (Selectable)
Output Frequency: 50Hz/60Hz (Selectable)
Overview
This series is a double conversion Power Converter which produces stable pure sine wave voltage and frequency output (O/P). With this Converter, you can protect your equipment from most power issues, including power sags, power surges, brownouts, and line noise. With the common neutral topology, the converter provides internal connection from AC I/P neutral to AC O/P neutral; thus, it does not need to use an isolation transformer to provide 0 volt from AC I/P neutral to O/P neutral. This feature will reduce the interference to loads of communication or video systems.
Features
Outstanding Performance & Reliability
Common Neutral, Double Conversion Topology (0/P Neutral to 1/P Neutral is O volts normally)
Wide Range Input Window and Input Power Factor Correction
Low Noise, Smart Cooling Fan Design
High Efficiency, New Full-bridge Inverter Design
Automatic Restart After Overload Shutdown
AC Input Generator Compatible
Remote Emergency Power Off
Multifunction LCD Screen
SPECIFICATIONS
STEP-UP Voltage and Frequency Converter (UX / Tower Series)
Models
UX-1K
UX-1.5K
UX-2K
UX-3K
Output
Capacity
1000VA/900W
1500VA/1350W
2000VA/1800W
3000VA/2700W *
Output Voltage
200V/220V/230V/240V Selectable
Voltage Waveform
Sine wave
Crest Factor
3:1
Output Frequency
(sync to mains)
50/60Hz (selectable from LCD function button)
Output Frequency
(not sync to mains)
50±0.01Hz or 60±0.01Hz
Regulation
±2% of selected output voltage
(adjustable by using the setting software)
Output Current
200 V ~ 240 V
4.2 Amp
6.3 Amp
8.4 Amp
12.5 Amp
Output Peak Current
(<250mS)
13 Amp
20 Amp
27 Amp
37 Amp
Overload protection
100%~129% for 60 seconds, then audible alarm; audible alarm sounds for 60 seconds before shutting down
>130%, alarm will go off for 2 seconds and then shutting down
Harmonic Distortion
<3% (at full resistive load)
Efficiency
Up to 90%
Input
Voltage Range
100V~285Vac
240 Volts Range: 180V~285V
Requires dedicated 240-volt power
Frequency Range
45~70Hz
Input current
10 Amp
15 Amp
20 Amp
20 Amp
Wall-Outlet Type Required
NEMA 5-15 R
(15 Amps)
NEMA 5-20 R
(20 Amps)
NEMA 5-20 R
(20 Amps)
NEMA 6-20 R
(20 Amps)
Power Factor
>=0.98
Surge Current
<100A, 3mS
Communications & Management
Control panel
LCD
Audible alarm
Overload alarm: Short-circuit alarm, Thermal alarm
Environmental and Safety
Operating Temp.
Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉)
Transit/storage Temp.
-15℃ to 55℃ (5℉ to 131℉)
Relative Humidity
5 - 95% non condensing
Operating Altitude
0 ~ 3000 meters
Audible noise
=<45 dBA (at 1 meter from surface of unit)
Safety Markings
BSMI
CE
Quality control system
ISO9001
Physical
Models
UX-1K
UX-1.5K
UX-2K
UX-3K
Dimensions
D x H x W
38×20×18cm
15×8×7in
45×20×18cm
18×8×7in
51×20×18cm
20×8×7in
51×20×18cm
20×8×7in
Weight
6.5 kg / 14.0 lbs
7.0 kg / 15.5 lbs
8.0 kg / 17.6 lbs
8.5 kg / 19.0 lbs
Shipping Dimensions
D x H x W; Weight
48.0×33.0×30.0cm; 8.5 kg
19.0×13.0×12.0in; 19.0 lbs
54.0×33.0×30.0cm; 9.0 kg
21.0×13.0×12.0in; 20.0 lbs
61.0×33.0×30.0cm; 10.0 kg
24.0×13.0×12.0in; 22.0 lbs
61×33×30cm; 10.5 kg
24×13×12in; 23.0 lbs
PS.“﹡” Please refer to the input range for the condition of output rated capacity.