-40%

NEW EMERSON ROSEMOUNT ALPHALINE® NUCLEAR PRESSURE TRANSMITTER 1153DB5PAN0016

$ 395.99

Availability: 100 in stock
  • DIFFERENTIAL CONFIGURATION: STATIC PRESSURE RATING 2000 PSIG
  • WELDED ⅜" SWAGELOK COMP FTGS: WELDED DRAIN/VENT VALVE
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • 0-125 to 0-750 psig in H₂O: Supply 45vdc max
  • Restocking Fee: No
  • Country/Region of Manufacture: United States
  • Brand: EMERSON ROSEMOUNT NUCLEAR
  • MPN: 1153DB5PAN0016
  • Condition: New
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • Model: SERIES 1153 ALPHALINE ® PRESSURE TRANSMITTER

    Description

    ONE NEW EMERSON ROSEMOUNT NUCLEAR ALPHALINE® NUCLEAR PRESSURE TRANSMITTER
    1153DB5PAN0016
    .
    Serial Number: 60-0508423
    Differential Configuration
    Static Pressure Rating 2000 psig (13.8 mPa)
    Painted Aluminum housing qualified per
    IEEE
    Stds. 323-1974, 323-1975
    Calibrated 0-125 to 0-750 psig in H₂O
    Output standard 4-20mA, maximum 45vdc supply
    Welded ⅜"
    Swagelok
    ®
    Compression Fitting Process Connectors
    Welded Drain/Vent Valve
    Alphaline® Nuclear Pressure Transmitter
    BOOKMARK THIS EBAY PAGE, THEN OPEN ANOTHER PAGE OF THIS BROWSER, AND COPY AND PASTE THESE URL'S INTO THE BROWSER'S WEB ADDRESS BAR, TO VISIT THEM (AND THEN, RETURN HERE)
    PRODUCT DATA SHEET      http://www2.emersonprocess.com/siteadmincenter/pm%20rosemount%20documents/00813-0100-4302.pdf
    PRODUCT INFORMATION PAGE      http://www2.emersonprocess.com/en-us/brands/rosemount/nuclear/1153-series-b/pages/index.aspx
    ROSEMOUNT TRANSMITTER 1153 SERIES B ALPHALINE NUCLEAR PRESSURE TRANSMITTER REFERENCE MANUAL      http://www2.emersonprocess.com/siteadmincenter/pm%20rosemount%20documents/00809-0100-4302.pdf
    PRODUCT DATA SHEET 1153 SERIES D      http://www2.emersonprocess.com/siteadmincenter/pm%20rosemount%20documents/00813-0100-4388.pdf
    The
    Rosemount 1153 Series B Alphaline® Pressure Transmitters
    are designed for precision pressure
    measurements in nuclear applications requiring reliable performance and safety over a specified
    qualified life. These transmitters were qualified per
    IEEE
    std. 323-1974 and
    IEEE
    std. 344-1975
    to
    radiation levels of 22 megarads TID gamma radiation, seismic levels of 4 g's, and for steam-pressure
    performance. Stringent quality control during the manufacturing process includes traceability of
    pressure-retaining parts, special nuclear cleaning, and hydrostatic testing.
    TRANSMITTER DESCRIPTION
    The
    Rosemount 1153 Transmitters
    are uniquely built for class
    1E
    nuclear service while retaining the
    working concept and design parameters of the
    Rosemount 1151 Series
    that have become a standard
    of reliable service. Units are available in Absolute (
    A
    ), Gage (
    G
    ), Differential (
    D
    ), and High-Line Differential
    (
    H
    ) configurations, with a variety of pressure range options.
    Direct electronic sensing with the completely sealed δ-Cell capacitance sensing element eliminates
    mechanical force transfer and problems associated with shock and vibration. Installation and
    commissioning are simplified by the compact design and 2-wire system compatibility. Wiring terminals and
    electronics are in separate compartments, so the electronics remain sealed during installation.
    The completely sealed δ-Cell capacitance sensing element is the key to the unequaled performance and
    reliability. Its simple design concept is recognized as a landmark in transmitter engineering. As shown in
    Figure 1, process pressure is transmitted through an isolating diaphragm and silicone oil fill fluid to a
    sensing diaphragm in the center of the δ -Cell. A reference pressure is transmitted in like manner to the
    other side of the sensing diaphragm.  Displacement of the sensing diaphragm, a maximum motion of 0.004 inches (0.1 mm), is proportional to the pressure differential across it. The position of the sensing diaphragm is detected by capacitor plates on both sides of the sensing diaphragm. Differential capacitance between the sensing diaphragm and the capacitor plates is converted electronically to a 2-wire, 4–20 mA DC signal.

    SAME DAY SHIPPING, NEXT DAY DELIVERY AVAILABLE, IF PURCHASED BY  4 PM EASTERN DAYLIGHT SAVINGS TIME.